Precise technical specifications and measurements for Odyssey HR2100 and H2400 below:
HR2100 |
H2400 |
|
Temperature and Humidity Monitoring: | – | |
Automated Temperature and Humidity Climate Control: | – | |
Living Space Ventilation: | ||
Roof Space Ventilation: | – | |
Control Panel: | 4.3″ LCD Touch Screen | On / Off Switch |
Roof Mounted Ventilator: | ||
Multiple Turbine Link: | – | |
Nominal system diameter: | 400 mm | |
Electrical: |
240 VAC 50 Hz Max. 75 W |
|
Ventilator: | Hybrid (natural & powered) backward curved centrifugal | |
Motor: | Electronic Commutating (EC) brushless motor | |
Turbine/Impeller diameter: | 500 mm | |
Flow Rate @ ΔpsF=0: | 2400 m3/hr | 2400 m3/hr |
Noise SPL @ 2m: | 36.5 dB(A) | |
Roof Slope Installation Range: | 3° to 35° | |
Roof Space Minimum Height: |
0.7 m (600mm rafter spacing) 0.85 m (450mm rafter spacing) |
0.25 m (600mm rafter spacing & 450mm rafter spacing) |
Roof Space Maximum Height: |
2.4 m (600mm rafter spacing) 2.55 m (450mm rafter spacing) |
2.25 m (600mm rafter spacing & 450mm rafter spacing) |
Diverter Valve: | 2 way, 2 position air source diverter valve | – |
Ducting: | 2 m Flexible metallised polyester film with helix wire support | |
Grille: | Return air type with magnetically detachable grille | |
Wall mounted control panel: | 8.8cm (3.5”) colour touch screen with 15m cable | 11cm Mechanical on/off switch |
Sensor accuracy | Temperature: ±0.4°C, Relative humidity: ±3% | Sensors not included |
ACH (Air Changes per Hour) | 7 | 7 |
Warranty Information | Download Odyssey Warranty Information |